<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-23 09-20-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.90 MHz 5/5, 60 dBuV SRF2
Pilot RDS Phase Difference
0.0 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
6 kHz 15 kHz 19053 0,0157
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-18,0 dBr -15,51 dBr -8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SRF2 " 43B2 0 (No PTY) 1 0 1 1 --:--
RT
" "
AF EON
88.5, 91.7, 93.0, 93.2, 93.7, 94.0, 94.9, 95.4, 96.6, 97.3, 97.7, 99.0, 99.1, 99.4, 99.5, 99.6, 100.7, 102.5, 103.2, 104.1, 104.9 MHz 43B3, 43B1
FM Scope Max at: 15 kHz MIN: 6 kHz % above 76 kHz: 0,0157 Acquired: 2026/01/23 9.19.51 Total samples: 19053 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: -8,5 dBr MIN: -18,0 dBr AVE: -15,51 dBr % above 12,2 dBr: 0,0 Last value: -12,2 dBr (2026/01/23 9.19.50) 09.06 09.08 09.10 09.12 09.14 09.16 09.18 -15 -10 -5 0 Pm [dBr]